ISO INTERNATIONAL STANDARD 9972 Third edition 2015-08-15 Thermal performance of buildings Determination of air permeability of buildings Fan pressurization method Performance thermique des batiments Détermination de la perméabilite a I'air des batiments - Methode de pressurisation par ventilateur Reference number IS0 9972:2015(E) ISO International Organization for Standardization eeZhejang Institute of Standardization 5956617 @IS02015 ed without license from IHS IS0 9972:2015(E) COPYRIGHT PROTECTED DOCUMENT IS0 2015, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form written permission. Permission can be requested from either ISO at the address below or ISO's member body in the country of the requester. ISOcopyrightoffice Ch. de Blandonnet 8 · CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 [email protected] www.iso.org Internatinir DrganizationforStandardization Not for Resale, 2015/11/11 08:34:20 networking permited withoutlicense from IHS IS0 9972:2015(E) Contents Page Foreword ..V Introduction.. ..vi 1 Scope. 2 Normative references 3 Terms, definitions, and symbols 3.1 Terms and definitions ..1 3.2 Symbols... 4 Apparatus. ..4 4.1 General .4 4.2 Eguipment 4.2.1 Air-moving equipment 4 4.2.2 Pressure-measuring device ..4 4.2.3 Air flow rate measuring system ..4 4.2.4 Temperature-measuring device .4 5 Measurement procedure. ..4 5.1 Measurement conditions. .4 5.1.1 General .4 5.1.2 Measured extent. .5 5.1.3 Time of measurement 5 5.2 Preparation .5 5.2.1 Building preparation methods 5 5.2.2 Heating, ventilation and air conditioning systems and other building equipment 5 5.2.3 Intentional openings in the envelope 6 5.2.4 Openings inside the measured extent 5.2.5 Air-moving equipment 7 5.2.6 Pressure measuring devices. .7 5.3 Steps of the procedure. .8 5.3.1 Preliminary check .8 5.3.2 Temperature and wind conditions .8 5.3.3 Zero-flow pressure difference. .8 5.3.4 Pressure difference sequence.. ..8 6 Expression of results .9 6.1 Reference values .9 6.1.1 Internal volume. 6.1.2 Envelope area. 9 6.1.3 Net floor area 10 6.2 Calculation of the air leakage rate .10 6.3 Derived quantities.. ..13 6.3.1 General. ..13 6.3.2 Air change rate at reference pressure difference .13 6.3.3 Specific leakage rate (envelope) .. 13 6.3.4 Specific leakage rate (floor). .14 6.3.5 Effective leakage area. ..14 6.3.6 Specific effective leakage area (envelope) ..14 6.3.7 Specific effective leakage area (floor) 7 Test report ..15 8 Uncertainty ..15 8.1 General ..15 8.2 Reference value ..16 8.3 Overall uncertainty. ..16 Annex A (informative) Description of equipment used to pressurize buildings ..17 ntemaional ganzation5-All rights reserved iii LicenseeZhejang Institute of Standardization 5956617 ed without license from IHS Not for Resale, 2015/11/11 08:34:20

.pdf文档 ISO 9972 2015 Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method

文档预览
中文文档 34 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共34页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO 9972 2015 Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method 第 1 页 ISO 9972 2015 Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method 第 2 页 ISO 9972 2015 Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2024-08-26 00:31:27上传分享
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。